5910-00-889-4300 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-00-889-4304 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-00-889-4302

Federal Supply Class:
5910

National Item Identification Number:
008894302

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CE52C450N81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CE52C450N81350JOINT ARMY-NAVY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC6281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPEPLAIN FOIL
BODY DIAMETER1.562 INCHES NOMINAL
BODY LENGTH3.437 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINAL(S) ON ONE END
CAPACITIVE ELECTRODE MATERIALALUMINUM
CAPACITANCE VALUE PER SECTION45.000 MICROFARADS ALL SECTIONS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT17.0000
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS197.0
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION300.0 DC 1ST SECTION AND 300.0 DC 2ND SECTION
NONDERATED OPERATING TEMP-40.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORONE TERMINAL COMMON TO EACH SECTION
SECTION QUANTITY2
TOLERANCE RANGE PER SECTION-10.00 TO 50.00 PERCENT 1ST SECTION AND -10.00 TO 50.00 PERCENT 2ND SECTION
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY3 STANDARD TUBE BASE
TEST DATA DOCUMENT81349-MIL-C-62 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).