5910-00-928-1126 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-00-928-1128 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-00-928-1127

Federal Supply Class:
5910

National Item Identification Number:
009281127

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
10199-5323127914HONEYWELL INTERNATIONAL INC DBA HONEYWELL
131-88-1125549LITTON SYSTEMS INC AMECOM DIV
K120P10K05397UNION CARBIDE CORP MATERIALS SYSTEMS DIV
T330D127K010AS05397UNION CARBIDE CORP MATERIALS SYSTEMS DIV
T330Z127K010AS05397UNION CARBIDE CORP MATERIALS SYSTEMS DIV
131-88-1192755NORTHROP GRUMMAN SYSTEMS CORP


Techincal Specification:
ANODE TYPESOLID
BODY HEIGHT0.195 INCHES NOMINAL
BODY LENGTH0.600 INCHES NOMINAL
BODY WIDTH0.375 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
CAPACITANCE VALUE PER SECTION120.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.195 INCHES MINIMUM AND 0.205 INCHES MAXIMUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT8.0000
ELECTRICAL POLARIZATIONPOLARIZED
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION10.0 DC SINGLE SECTION
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL LENGTH1.500 INCHES NOMINAL
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT97983-131-86 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial