5940-01-055-1155 TERMINAL,QUICK DISCONNECT Index 5910-01-055-1157 CAPACITOR,FIXED,MICA DIELECTRIC

National Stock Number:
5910-01-055-1156

Federal Supply Class:
5910

National Item Identification Number:
010551156

Description:
CAPACITOR,FIXED,MICA DIELECTRIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
815234-0013K0385THALES UK LIMITED DBA THALES UK LTDAVIONICS
CM04ED270J0381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-5/1881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.190 INCHES MAXIMUM
BODY LENGTH0.360 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY WIDTH0.330 INCHES MAXIMUM
CAPACITANCE VALUE PER SECTION27.000 PICOFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.150 INCHES NOMINAL
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.0007
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
MATERIALPLASTIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION500.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS-20.0 TO 100.0 SINGLE SECTION
TERMINAL LENGTH1.000 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-5/18 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-5.00 TO 5.00 PERCENT SINGLE SECTION