5905-01-129-0052 RESISTOR,VARIABLE,WIRE WOUND,NON Index 5910-01-129-0054 CAPACITOR,FIXED,CERAMIC DIELECTR

National Stock Number:
5910-01-129-0053

Federal Supply Class:
5910

National Item Identification Number:
011290053

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
18125A332GA72A04222KYOCERA AVX COMPONENTS CORPORATION
18125A332GA806004222KYOCERA AVX COMPONENTS CORPORATION
913-3669-31013499ROCKWELL COLLINS, INC.
A09C7C0G332G18796MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS
A09C7C0G332G72982ERIE SPECIALTY PRODUCTS INC
GRM43-2C0G332J100V72982ERIE SPECIALTY PRODUCTS INC
R-3123-3100TCV9ARIZONA CAPACITORS, INC
VJ1812A332G-XB95275VITRAMON INC PO BOX 544 BRIDGEPORT CT 06601
VJ1812A332GXBAB95275VITRAMON INC PO BOX 544 BRIDGEPORT CT 06601
R-3123-31096733SFE TECHNOLOGIES


Techincal Specification:
BODY HEIGHT0.020 INCHES MINIMUM AND 0.080 INCHES MAXIMUM
BODY LENGTH0.180 INCHES NOMINAL
BODY STYLECHIP TYPE
BODY WIDTH0.125 INCHES NOMINAL
CAPACITANCE VALUE PER SECTION3300.000 PICOFARADS SINGLE SECTION
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.140 INCHES NOMINAL
CRITICALITY CODE JUSTIFICATIONFEAT
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT1.5000
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
MATERIALCERAMIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION100.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS0.0 SINGLE SECTION
TERMINAL LENGTH0.020 INCHES NOMINAL
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 BONDING PAD
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS-30.0 TO 30.0 SINGLE SECTION
TOLERANCE RANGE PER SECTION-2.00 TO 2.00 PERCENT SINGLE SECTION