5910-01-132-6517 CAPACITOR,FIXED,CERAMIC DIELECTR Index 5920-01-132-6521 FUSE,CARTRIDGE

National Stock Number:
5910-01-132-6518

Federal Supply Class:
5910

National Item Identification Number:
011326518

Description:
CAPACITOR,FIXED,CERAMIC DIELECTR

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
4111888-68405869RAYTHEON COMPANY
948187-49506481NORTHROP GRUMMAN SYSTEMS CORPORATION
M39014/22-049581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39014/2281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.128 INCHES NOMINAL
BODY LENGTH0.260 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES
BODY WIDTH0.090 INCHES MINIMUM AND 0.092 INCHES MAXIMUM
CAPACITANCE VALUE PER SECTION0.100 MICROFARADS SINGLE SECTION
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT2.5000
INSULATION RESISTANCE AT REFERENCE TEMP100000.0 MEGOHMS
MATERIALPLASTIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 125.0 CELSIUS MAXIMUM
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.1000
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE-25.0 TO 15.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION
TERMINAL LENGTH0.148 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 RIBBON
TEST DATA DOCUMENT81349-MIL-C-39014/22 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-20.00 TO 20.00 PERCENT SINGLE SECTION