DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 2.5000 |
BODY HEIGHT | 0.090 INCHES NOMINAL |
BODY LENGTH | 0.190 INCHES NOMINAL |
BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
BODY WIDTH | 0.190 INCHES NOMINAL |
CAPACITANCE VALUE PER SECTION | 10000.000 PICOFARADS SINGLE SECTION |
CASE MATERIAL | PLASTIC |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.200 INCHES NOMINAL |
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 10000.0 MEGOHMS |
INSULATION RESISTANCE AT REFERENCE TEMP | 100000.0 MEGOHMS |
PROPRIETARY CHARACTERISTICS | PACS |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 200.0 DC SINGLE SECTION |
NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
RELIABILITY INDICATOR | ESTABLISHED |
SPECIFICATION/STANDARD DATA | 81349-MIL-C-39014D/1D-1330 GOVERNMENT SPECIFICATION |
SPECIAL FEATURES | SELECTED ITEM;RADIOGRAPHIC INSPECTED |
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE | -25.0/+15.0 WITH RATED VOLTAGE APPLIED SINGLE SECTION |
TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
TERMINAL LENGTH | 1.250 INCHES MINIMUM |
TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
TEST DATA DOCUMENT | 98230-0N516232 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION |