5340-01-143-0206 CLIP,SPRINGTENSION Index 5905-01-143-0209 RESISTOR,FIXED,WIRE WOUND

National Stock Number:
5910-01-143-0208

Federal Supply Class:
5910

National Item Identification Number:
011430208

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
116783228528ITT INDUSTRIES INC ITT AEROSPACE COMMUNICATIONS DIV EAST
3192FE223T030AMA56699BC COMPONENTS
3192FE223T030AMA156699BC COMPONENTS
71C40CC21380031MEPCO/ELECTRA INC
M39018/04-113681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
5910PL14309009009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
M39018/04-2084M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39018/04-2136M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39018/4-213681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-0039018/481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39018/481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39018/481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
BODY DIAMETER2.500 INCHES NOMINAL
BODY LENGTH4.125 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, TERMINAL(S) ON ONE END
CAPACITANCE VALUE PER SECTION22000.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALALUMINUM
CASE INSULATION MATERIALPLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER1.125 INCHES NOMINAL
DC LEAKAGE AT MAXIMUM OPERATING TEMP8.22 MILLIAMPERES
DC LEAKAGE AT REFERENCE TEMP1.370 MILLIAMPERES
EQUIVALENT SERIES RESISTANCE AT REFERENCE TEMP IN OHMS0.019
IMPEDANCE AT MINIMUM OPERATING TEMP IN OHMS0.19
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION40.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.0000
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIFICATION/STANDARD DATA81349-MIL-C-39018/4 GOVERNMENT SPECIFICATION
TERMINAL DIAMETER0.190 INCHES NOMINAL
TERMINAL LENGTH0.281 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 THREADED HOLE
TERMINAL SURFACE TREATMENTSOLDER
TEST DATA DOCUMENT81349-MIL-C-39018 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 50.00 PERCENT SINGLE SECTION