5910-01-257-9583 CAPACITOR,FIXED,ELECTROLYTIC Index 5935-01-257-9585 SOCKET,PLUG-IN ELECTRONIC COMPON

National Stock Number:
5910-01-257-9584

Federal Supply Class:
5910

National Item Identification Number:
012579584

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
80170900000A3489PLESSEY SPA
999/4/43079/024K0668LEONARDO UK LTD
CX06M475K81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-49137/681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-49137/681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY HEIGHT0.260 INCHES MINIMUM AND 0.290 INCHES MAXIMUM
BODY LENGTH0.195 INCHES MINIMUM AND 0.220 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY WIDTH0.075 INCHES MINIMUM AND 0.110 INCHES MAXIMUM
CAPACITIVE ELECTRODE MATERIALTANTALUM
CAPACITANCE VALUE PER SECTION4.700 MICROFARADS SINGLE SECTION
CASE INSULATION MATERIALPLASTIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH0.180 INCHES NOMINAL
DC LEAKAGE AT REFERENCE TEMP2.000 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT6.000
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION35.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORNOT ESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION
SPECIFICATION/STANDARD DATA81349-MIL-C-49137/6 GOVERNMENT SPECIFICATION
TERMINAL DIAMETER0.016 INCHES NOMINAL
TERMINAL LENGTH1.000 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-49137 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).