5910-01-278-7144 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-01-278-7146 CAPACITOR,FIXED,METALLIZED,PAPER

National Stock Number:
5910-01-278-7145

Federal Supply Class:
5910

National Item Identification Number:
012787145

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
2073627-070106845RAYTHEON COMPANY
CSR13H156KR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
CSR13H156KS81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39003/01-290181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39003/01-290281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39003/01-314181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39003/01-630281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39003/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS39003-01-266181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPESOLID
BODY DIAMETER0.336 INCHES MINIMUM AND 0.367 INCHES MAXIMUM
BODY LENGTH0.755 INCHES MINIMUM AND 0.817 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION15.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
CASE INSULATION MATERIALPLASTIC
CRITICALITY CODE JUSTIFICATIONFEAT
DC LEAKAGE AT MAXIMUM OPERATING TEMP140.0 MICROAMPERES
DC LEAKAGE AT REFERENCE TEMP7.000 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT6.000
FEATURES PROVIDEDHERMETICALLY SEALED CASE
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-4
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION75.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.100
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
SPECIAL FEATURESWEIBULL GRADED FAILURE RATE
SPECIFICATION/STANDARD DATA81349-MIL-C-39003/1 GOVERNMENT SPECIFICATION
TERMINAL DIAMETER0.023 INCHES MINIMUM AND 0.027 INCHES MAXIMUM
TERMINAL LENGTH1.250 INCHES MINIMUM AND 1.750 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION