5910-01-288-4135 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-01-288-4137 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-01-288-4136

Federal Supply Class:
5910

National Item Identification Number:
012884136

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
M39003/01-527281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39003/01-817881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39003/1-527281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39003/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39003/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ANODE TYPESOLID
BODY DIAMETER0.120 INCHES MINIMUM AND 0.151 INCHES MAXIMUM
BODY LENGTH0.255 INCHES MINIMUM AND 0.317 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION0.330 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
CASE INSULATION MATERIALPLASTIC
CRITICALITY CODE JUSTIFICATIONFEAT
DC LEAKAGE AT MAXIMUM OPERATING TEMP5.0 MICROAMPERES
DC LEAKAGE AT REFERENCE TEMP0.300 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT2.000
ELECTRICAL POLARIZATIONPOLARIZED
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-4
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION50.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
SPECIAL FEATURESWEIBULL GRADED FAILURE RATE
SPECIFICATION/STANDARD DATA81349-MIL-C-39003/1 GOVERNMENT SPECIFICATION
TERMINAL LENGTH1.250 INCHES MINIMUM AND 1.750 INCHES MAXIMUM
TERMINAL DIAMETER0.018 INCHES MINIMUM AND 0.022 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-5.00 TO 5.00 PERCENT SINGLE SECTION


Click here to Register for Free 30-day Trial