5910-01-288-4137 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-01-288-4139 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-01-288-4138

Federal Supply Class:
5910

National Item Identification Number:
012884138

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
5910PL09269859009HINSPEKTORAT WSPARCIA SIL ZBROJNYCH
K560A10S05397UNION CARBIDE CORP MATERIALS SYSTEMS DIV
M39003/03-023181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39003/03-033181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39003/03-303181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39003/03-403181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-39003/381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39003/381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ANODE TYPESOLID
BODY DIAMETER0.336 INCHES MINIMUM AND 0.367 INCHES MAXIMUM
BODY LENGTH0.817 INCHES MINIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION560.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
CASE INSULATION MATERIALPLASTIC
CRITICALITY CODE JUSTIFICATIONFEAT
DC LEAKAGE AT MAXIMUM OPERATING TEMP300.0 MICROAMPERES
DC LEAKAGE AT REFERENCE TEMP30.000 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT10.000
ELECTRICAL POLARIZATIONPOLARIZED
FEATURES PROVIDEDHERMETICALLY SEALED CASE
MIL-STD-1276 WIRE LEAD TYPE DESIGNATORN-4
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION10.0 DC SINGLE SECTION
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.001
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
SPECIAL FEATURESWEIBULL GRADED FAILURE RATE
SPECIFICATION/STANDARD DATA81349-MIL-C-39003/3 GOVERNMENT SPECIFICATION
TERMINAL LENGTH1.250 INCHES MINIMUM AND 1.750 INCHES MAXIMUM
TERMINAL DIAMETER0.025 INCHES MINIMUM
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-39003 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION