5910-01-296-3462 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-01-296-3464 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-01-296-3463

Federal Supply Class:
5910

National Item Identification Number:
012963463

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CWR03JD226KM81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-55365/281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-55365/281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY HEIGHT0.190 INCHES MINIMUM AND 0.200 INCHES MAXIMUM
BODY LENGTH0.315 INCHES MINIMUM AND 0.325 INCHES MAXIMUM
BODY STYLECHIP TYPE WITH TAPE TERMINALS
BODY WIDTH0.170 INCHES MINIMUM AND 0.190 INCHES MAXIMUM
CAPACITANCE VALUE PER SECTION22.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
CASE MATERIALPLASTIC
DC LEAKAGE AT MAXIMUM OPERATING TEMP88.0 MICROAMPERES
DC LEAKAGE AT REFERENCE TEMP8.800 MICROAMPERES
NONDERATED OPERATING TEMP-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION20.0 DC SINGLE SECTION
RELIABILITY INDICATORESTABLISHED
RELIABILITY FAILURE RATE LEVEL IN PERCENT1.000
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
TEST DATA DOCUMENT81349-MIL-C-55365 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00/+10.00 PERCENT SINGLE SECTION
SPECIFICATION/STANDARD DATA81349-MIL-C-55365/2 GOVERNMENT SPECIFICATION
TERMINAL LENGTH0.150 INCHES MINIMUM AND 0.170 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY2 BONDING PAD
TERMINAL SURFACE TREATMENTSOLDER
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT6.000
ELECTRICAL POLARIZATIONPOLARIZED
ANODE TYPEPLAIN FOIL


Click here to Register for Free 30-day Trial