5910-01-334-1322 CAPACITOR,FIXED,ELECTROLYTIC Index 5910-01-334-1324 CAPACITOR,FIXED,METALLIZED,PAPER

National Stock Number:
5910-01-334-1323

Federal Supply Class:
5910

National Item Identification Number:
013341323

Description:
CAPACITOR,FIXED,METALLIZED,PAPER

Detail:
A capacitor whose capacitance value cannot be adjusted or varied having paper, plastic, or any combination of paper and plastic as the dielectric material with a metallic film deposited thereon. It may be a single unit or consist of two or more units which cannot be separated.


Manufacturer Information:
CFR13ALC206JP81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-55514/981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-55514/981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
BODY DIAMETER1.190 INCHES MINIMUM AND 1.440 INCHES MAXIMUM
BODY LENGTH2.188 INCHES MINIMUM AND 2.312 INCHES MAXIMUM
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION20.000 PICOFARADS SINGLE SECTION
DIELECTRIC MATERIALPLASTIC POLYPROPYLENE
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT0.100
INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP1000.0 MEGOHM-MICROFARADS
INSULATION RESISTANCE AT REFERENCE TEMP200000.0 MEGOHM-MICROFARADS
MATERIALPLASTIC CASE
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION200.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-55.0 CELSIUS MINIMUM AND 105.0 CELSIUS MAXIMUM
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.100
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIFICATION/STANDARD DATA81349-MIL-C-55514/9 GOVERNMENT SPECIFICATION
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS0.0 SINGLE SECTION
TERMINAL DIAMETER0.040 INCHES NOMINAL
TERMINAL LENGTH1.750 INCHES MINIMUM
TERMINAL SURFACE TREATMENTSOLDER
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MIL-C-55514 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS-3.5 TO 2.0 SINGLE SECTION
TOLERANCE RANGE PER SECTION-5.00 TO 5.00 PERCENT SINGLE SECTION