5895-01-465-2657 SWITCHING GROUP,DIGITAL DATA Index 5910-01-465-2659 CAPACITOR,FIXED,CERAMIC DIELECTR

National Stock Number:
5910-01-465-2658

Federal Supply Class:
5910

National Item Identification Number:
014652658

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
CWR06FC336KR81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-55365/481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-55365/481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
ELECTRICAL POLARIZATIONNONPOLARIZED
BODY HEIGHT0.095 INCHES MINIMUM AND 0.125 INCHES MAXIMUM
BODY LENGTH0.250 INCHES MINIMUM AND 0.280 INCHES MAXIMUM
BODY STYLECHIP TYPE
BODY WIDTH0.095 INCHES MINIMUM AND 0.125 INCHES MAXIMUM
CAPACITANCE VALUE PER SECTION33.300 PICOFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALTANTALUM
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT10.000
NONDERATED OPERATING TEMP85.0 CELSIUS MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION10.0 DC SINGLE SECTION
RELIABILITY FAILURE RATE LEVEL IN PERCENT0.010
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORNO COMMON OR GROUNDED ELECTRODE(S)
SPECIFICATION/STANDARD DATA81349-MIL-PRF-55365/4E GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY2 BONDING PAD
TEST DATA DOCUMENT81349-55365 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 10.00 PERCENT SINGLE SECTION