5955-00-069-5044 CRYSTAL UNIT,QUARTZ Index 5915-00-069-5046 FILTER,BAND PASS

National Stock Number:
5915-00-069-5045

Federal Supply Class:
5915

National Item Identification Number:
000695045

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
18628-442498DAR ELECTRONICS INC DBA NATIONAL RADIO CO
330697-180249BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION225.0 HERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 BLANK
INCLOSURE TYPEENCASED
FREQUENCY BAND WIDTH PER FUNCTION150.00 HERTZ BLANK AND
300.00 HERTZ BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
2 TAB, SOLDER LUG GROUND 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
INPUT IMPEDANCE PER FUNCTION W/LOAD600.0 OHMS BLANK
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT600.0 OHMS BLANK
OVERALL HEIGHT4.500 INCHES NOMINAL
BODY LENGTH2.251 INCHES NOMINAL
BODY HEIGHT4.000 INCHES NOMINAL
BODY WIDTH1.999 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.375 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.375 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.190 INCHES
TEST DATA DOCUMENT80249-330697-1 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION50.00 HERTZ BLANK AND
150.00 HERTZ BLANK AND
300.00 HERTZ BLANK AND
850.00 HERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND
4.0 MAXIMUM BLANK 1ST FUNCTION
OPERATING TEMP RANGE0.0 TO 60.0 DEG CELSIUS
BODY MATERIALMETAL
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: LB4.000