5915-00-106-0297 FILTER,BAND PASS Index 5915-00-106-0299 FILTER,BAND PASS

National Stock Number:
5915-00-106-0298

Federal Supply Class:
5915

National Item Identification Number:
001060298

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
G349548-406KW9LUCENT TECHNOLOGIES INC DBA FEDERAL MARKETING GROUP
GS65626L401714LUCENT TECHNOLOGIES INC ADVANCED TECHNOLOGY SYSTEMS
GS65626L406KW9LUCENT TECHNOLOGIES INC DBA FEDERAL MARKETING GROUP
GS65626L43B4M0LUCENT TECHNOLOGIES INC CORPORATE HEADQUARTERS
GS65626L464959AMERICAN TELEPHONE AND TELEGRAPH CO


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION30.0 KILOHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.0 BLANK
INCLOSURE TYPEHERMETICALLY SEALED
FREQUENCY BAND WIDTH PER FUNCTION29.00 KILOHERTZ BLANK AND
31.00 KILOHERTZ BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
1 TAB, SOLDER LUG GROUND 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
SOURCE IMPEDANCE RATING PER FUNCTION55.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION55.0 OHMS BLANK
OVERALL HEIGHT4.580 INCHES MAXIMUM
BODY LENGTH2.580 INCHES MAXIMUM
BODY HEIGHT4.260 INCHES MAXIMUM
BODY WIDTH2.420 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED STUD 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.400 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.560 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
NOMINAL THREAD SIZE0.190 INCHES
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION28.00 KILOHERTZ BLANK AND
29.00 KILOHERTZ BLANK AND
31.00 KILOHERTZ BLANK AND
32.00 KILOHERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND
30.0 MAXIMUM BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 500.0
OPERATING TEMP RANGE-55.0 TO 85.0 DEG CELSIUS
BODY MATERIALMETAL


Click here to Register for Free 30-day Trial