5865-00-228-5776 CIRCUIT CARD ASSEMBLY Index 5950-00-228-5782 TRANSFORMER,PULSE

National Stock Number:
5915-00-228-5778

Federal Supply Class:
5915

National Item Identification Number:
002285778

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
10B49713058SORA POWER INC.
F2029696733SFE TECHNOLOGIES
S112744-102294MARATHONNORCO AEROSPACE, INC.
SM-D-63334-380063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
OPERATING CURRENT RATING PER FUNCTION IN AMPS50.0 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 2ND RADIO INTERFERENCE 2ND FUNCTION
25.0 3RD RADIO INTERFERENCE 3RD FUNCTION
25.0 4TH RADIO INTERFERENCE 4TH FUNCTION
INCLOSURE TYPEENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 THREADED STUD INPUT 1ST FUNCTION
4 THREADED STUD OUTPUT 2ND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY6 UNTHREADED HOLE
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION230.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
230.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
20.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
20.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 1ST RADIO INTERFERENCE 1ST FUNCTION
60.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OVERALL HEIGHT6.500 INCHES NOMINAL
BODY LENGTH5.000 INCHES MAXIMUM
BODY HEIGHT3.500 INCHES MAXIMUM
BODY WIDTH2.125 INCHES NOMINAL
UNTHREADED MOUNTING HOLE DIAMETER0.250 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.000 INCHES NOMINAL
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCAPACITANCE-INDUCTANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
CAPACITANCE-INDUCTANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
CAPACITANCE-INDUCTANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
CAPACITANCE-INDUCTANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE500.0 VOLTS AT SEA LEVEL
OPERATING TEMP RANGE-60.0 TO 85.0 DEG CELSIUS
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN


Click here to Register for Free 30-day Trial