BODY MATERIAL | METAL |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 20.0 NOMINAL BLANK AND 8.5 NOMINAL BLANK 1ST FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG INPUT 1ST FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG GROUND 3RD FUNCTION |
FREQUENCY BAND WIDTH PER FUNCTION | 4.752 KILOHERTZ BLANK AND 4.848 KILOHERTZ BLANK |
INCLOSURE TYPE | HERMETICALLY SEALED |
INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS BLANK |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 8.5 BLANK |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 1.0 KILOVOLTS AT SEA LEVEL |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
NOMINAL THREAD SIZE | 0.190 INCHES |
OPERATING TEMP RANGE | -54.0 TO 85.0 CELSIUS |
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 50.0 OHMS BLANK |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
REFERENCE FREQUENCY PER FUNCTION | 4.8 KILOHERTZ BLANK |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 3.60 KILOHERTZ BLANK AND 4.752 KILOHERTZ BLANK AND 4.848 KILOHERTZ BLANK AND 6.00 KILOHERTZ BLANK |