5975-00-256-3555 CONDUIT ASSEMBLY,METAL,FLEXIBLE Index 5305-00-256-3561 SCREW,MACHINE

National Stock Number:
5915-00-256-3560

Federal Supply Class:
5915

National Item Identification Number:
002563560

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
6505815-00112436BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
FLX23223954PHYSICAL ELECTRONICS LABORATORIES
WJ-623-2914482WATKINS-JOHNSON CO


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION12.2 GIGAHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK
INCLOSURE TYPEHERMETICALLY SEALED
FREQUENCY BAND WIDTH PER FUNCTION12.1825 GIGAHERTZ BLANK AND
12.2175 GIGAHERTZ BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION2.0 BLANK
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION12.1825 GIGAHERTZ BLANK AND
12.2175 GIGAHERTZ BLANK
OVERALL LENGTH2.760 INCHES NOMINAL
BODY LENGTH2.000 INCHES NOMINAL
BODY HEIGHT2.000 INCHES NOMINAL
BODY WIDTH2.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.700 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.700 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
FEATURES PROVIDEDTUNABLE
FREQUENCY TUNING METHODYTTRIUM-IRON GARNET CRYSTAL
TUNABLE FREQUENCY RANGE12.1825 GIGAHERTZ MINIMUM AND
12.2175 GIGAHERTZ MAXIMUM
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION12.165 GIGAHERTZ BLANK AND
12.1825 GIGAHERTZ BLANK AND
12.2175 GIGAHERTZ BLANK AND
12.235 GIGAHERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND
40.0 MAXIMUM BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCRYSTAL BLANK
OPERATING TEMP RANGE0.0 TO 65.0 DEG CELSIUS
PRECIOUS MATERIALGOLD
PRECIOUS MATERIAL AND LOCATIONCONTACT SURFACES GOLD
BODY MATERIALMETAL
SPECIAL FEATURESYIG FILTER