BODY HEIGHT | 2.380 INCHES NOMINAL |
BODY LENGTH | 3.960 INCHES NOMINAL |
BODY WIDTH | 3.660 INCHES NOMINAL |
CRITICALITY CODE JUSTIFICATION | FEAT |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.875 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.100 INCHES NOMINAL |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 WIRE LEAD INPUT 1ST FUNCTION |
INCLOSURE TYPE | ENCASED |
INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
INPUT IMPEDANCE PER FUNCTION W/LOAD | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
OVERALL HEIGHT | 14.480 INCHES NOMINAL |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 600.0 VOLTS AT SEA LEVEL |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.8 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.8 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.8 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
NOMINAL THREAD SIZE | 0.164 INCHES |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 18.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 18.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 18.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 420.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 420.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 420.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 500.0 |