5325-00-327-4381 COVER,SNAPSLIDE Index 5998-00-327-4390 CIRCUIT CARD ASSEMBLY

National Stock Number:
5915-00-327-4383

Federal Supply Class:
5915

National Item Identification Number:
003274383

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
3826992755NORTHROP GRUMMAN SYSTEMS CORP
FBD1240PW72BAE SYSTEMS AEROSPACE ELECTRONICS INC
FBD12455908METROPOLE PRODUCTS, INC.


Techincal Specification:
BODY WIDTH1.500 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS70.0 MINIMUM 1ST BAND PASS AND 2.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS70.0 MINIMUM 2ND BAND PASS AND 2.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.750 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION43.00 MEGAHERTZ 1ST BAND PASS AND 77.00 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION43.00 MEGAHERTZ 2ND BAND PASS AND 77.00 MEGAHERTZ 2ND BAND PASS 2ND FUNCTION
INCLOSURE TYPEENCASED
INPUT TERMINAL MANUFACTURER CODE92755
INPUT TERMINAL IDENTIFICATION12819FEMALE
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.0 1ST BAND PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.0 2ND BAND PASS 2ND FUNCTION
OVERALL HEIGHT0.650 INCHES MAXIMUM
OVERALL LENGTH4.250 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.112 INCHES
OUTPUT TERMINAL IDENTIFICATION12819FEMALE
OUTPUT TERMINAL MANUFACTURER CODE92755
REFERENCE FREQUENCY PER FUNCTION60.0 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION
REFERENCE FREQUENCY PER FUNCTION60.0 MEGAHERTZ 2ND BAND PASS 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION25.00 MEGAHERTZ 1ST BAND PASS AND 43.00 MEGAHERTZ 1ST BAND PASS AND 77.00 MEGAHERTZ 1ST BAND PASS AND 95.00 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION25.00 MEGAHERTZ 2ND BAND PASS AND 43.00 MEGAHERTZ 2ND BAND PASS AND 77.00 MEGAHERTZ 2ND BAND PASS AND 95.00 MEGAHERTZ 2ND BAND PASS 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION43.0 MEGAHERTZ 1ST BAND PASS AND 77.0 MEGAHERTZ 1ST BAND PASS 1ST FUNCTION
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION43.0 MEGAHERTZ 2ND BAND PASS AND 77.0 MEGAHERTZ 2ND BAND PASS 2ND FUNCTION
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 1ST BAND PASS 1ST FUNCTION
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 2ND BAND PASS 2ND FUNCTION
UNTHREADED MOUNTING HOLE DIAMETER0.136 INCHES NOMINAL


Click here to Register for Free 30-day Trial