5935-00-350-8193 CONNECTOR,RECEPTACLE,ELECTRICAL Index 5915-00-350-8196 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-00-350-8195

Federal Supply Class:
5915

National Item Identification Number:
003508195

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
5003-42150LSP2SPECTRUM CONTROL, INC.
5003-421513050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
SC5915-0012-112115DRS ICAS, LLC


Techincal Specification:
BODY HEIGHT2.000 INCHES NOMINAL
BODY LENGTH2.000 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH2.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG GROUND 3RD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
INCLOSURE TYPEENCASED
INPUT TERMINAL IDENTIFICATIONMS3112E-8-4S
INPUT TERMINAL MANUFACTURER CODE96906
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
OVERALL LENGTH2.500 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
NOMINAL THREAD SIZE0.138 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES