5930-00-392-7543 SWITCH,ROTARY Index 5930-00-392-7558 SWITCH,ROTARY

National Stock Number:
5915-00-392-7548

Federal Supply Class:
5915

National Item Identification Number:
003927548

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
1709180089EMERSON ELECTRIC CO WHITE-RODGERS DIV
SMC10881480063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
TS39007294GENISCO FILTER CORP
TS39013050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
ZM2457057NAVCOM DEFENSE ELECTRONICS, INC.
SMD10881480063US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR


Techincal Specification:
BODY HEIGHT3.375 INCHES MAXIMUM
BODY LENGTH2.250 INCHES MAXIMUM
BODY WIDTH1.500 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 NOMINAL 2ND LOW PASS AND 40.0 NOMINAL 2ND LOW PASS 2ND FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 NOMINAL 1ST LOW PASS AND 40.0 NOMINAL 1ST LOW PASS 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.000 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TURRET GROUND 3RD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TURRET INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TURRET OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION80.00 HERTZ 1ST LOW PASS AND 140.00 HERTZ 1ST LOW PASS 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION80.00 HERTZ 2ND LOW PASS AND 300.00 HERTZ 2ND LOW PASS 2ND FUNCTION
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD100.0 KILOHMS 1ST LOW PASS 1ST FUNCTION
INPUT IMPEDANCE PER FUNCTION W/LOAD100.0 KILOHMS 2ND LOW PASS 2ND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST LOW PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND LOW PASS 2ND FUNCTION
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT100.0 KILOHMS 1ST LOW PASS 1ST FUNCTION
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT100.0 KILOHMS 2ND LOW PASS 2ND FUNCTION
OVERALL HEIGHT3.750 INCHES MAXIMUM
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
NOMINAL THREAD SIZE0.164 INCHES
REFERENCE FREQUENCY PER FUNCTION110.0 HERTZ 1ST LOW PASS 1ST FUNCTION
REFERENCE FREQUENCY PER FUNCTION190.0 HERTZ 2ND LOW PASS 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION80.00 HERTZ 1ST LOW PASS AND 140.00 HERTZ 1ST LOW PASS AND 240.00 HERTZ 1ST LOW PASS AND 480.00 HERTZ 1ST LOW PASS 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION80.00 HERTZ 2ND LOW PASS AND 300.00 HERTZ 2ND LOW PASS AND 500.00 HERTZ 2ND LOW PASS AND 1.00 KILOHERTZ 2ND LOW PASS 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE