1560-00-524-1647 COVER,ACCESS Index 5961-00-524-1655 TRANSISTOR

National Stock Number:
5915-00-524-1650

Federal Supply Class:
5915

National Item Identification Number:
005241650

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
1M122-407294GENISCO FILTER CORP
1M122-413050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
5003-466213050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
1M122-422915NORTHROP GRUMMAN CORP ELECTRONIC SYSTEMS DEFENSIVE SYSTEM DIV
A-304123939THE CAPTOR CORPORATION


Techincal Specification:
OPERATING CURRENT RATING PER FUNCTION IN AMPS3.5 1ST RADIO INTERFERENCE 1ST FUNCTION
3.5 2ND RADIO INTERFERENCE 2ND FUNCTION
0.2 3RD RADIO INTERFERENCE 3RD FUNCTION
0.2 4TH RADIO INTERFERENCE 4TH FUNCTION
INCLOSURE TYPEENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
4 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 SLOT
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ADJACENT SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
28.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION2.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
2.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OVERALL LENGTH3.969 INCHES NOMINAL
OVERALL HEIGHT4.368 INCHES NOMINAL
OVERALL WIDTH1.320 INCHES NOMINAL
BODY LENGTH3.150 INCHES NOMINAL
BODY WIDTH1.270 INCHES NOMINAL
MOUNTING SLOT WIDTH0.250 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.625 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.526 INCHES NOMINAL
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE-RESISTANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
INDUCTANCE-CAPACITANCE-RESISTANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
MAXIMUM TEMP RISE15.0 DEG CELSIUS
INPUT TERMINAL MANUFACTURER CODE81349
INPUT TERMINAL IDENTIFICATIONM81511-02HB02P1
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 2000.0
OPERATING TEMP RANGE-65.0 TO 110.0 DEG CELSIUS


Click here to Register for Free 30-day Trial