Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
9100-300828480HEWLETT-PACKARD COMPANY


Techincal Specification:
OPERATING CURRENT RATING PER FUNCTION IN AMPS6.0 1ST RADIO INTERFERENCE 1ST FUNCTION
6.0 2ND RADIO INTERFERENCE 2ND FUNCTION
INCLOSURE TYPEENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
2 WIRE LEAD OUTPUT 2ND FUNCTION
1 TAB, SOLDER LUG GROUND 3RD FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 TERMINAL
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ADJACENT SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION230.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
230.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OVERALL LENGTH2.695 INCHES NOMINAL
OVERALL HEIGHT1.550 INCHES NOMINAL
BODY LENGTH1.181 INCHES NOMINAL
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
BODY MATERIALMETAL