AVERAGE LIFE RATING IN HOURS | 10000.0 |
BODY MATERIAL | METAL |
BODY LENGTH | 6.000 INCHES NOMINAL |
BODY WIDTH | 6.000 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 5.000 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 6.500 INCHES NOMINAL |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD INPUT AND 4 WIRE LEAD OUTPUT AND 1 THREADED STUD GROUND |
INCLOSURE TYPE | HERMETICALLY SEALED |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 130.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 130.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 130.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 130.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
OVERALL HEIGHT | 2.500 INCHES NOMINAL |
OVERALL LENGTH | 7.000 INCHES NOMINAL |
MAXIMUM VOLTAGE DROP PER FUNCTION | 2.4 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 2.4 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 2.4 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 2.4 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING TEMP RANGE | -55.0 TO 85.0 CELSIUS |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 440.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
UNTHREADED MOUNTING HOLE DIAMETER | 0.196 INCHES NOMINAL |