1560-00-632-2374 COVER,ANTENNA HOUSI Index 5910-00-632-2376 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5915-00-632-2375

Federal Supply Class:
5915

National Item Identification Number:
006322375

Description:
FILTER,LOW PASS

Detail:
An item designed to pass all frequencies below a specified frequency. Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
241-0643-01013499ROCKWELL COLLINS, INC.
263227834MICROWAVE FILTER CO INC
3340021-00192755NORTHROP GRUMMAN SYSTEMS CORP


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION100.0 WATTS BLANK
BODY LENGTH6.000 INCHES NOMINAL
BODY WIDTH3.000 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS1.0 MAXIMUM BLANK AND 100.0 MINIMUM BLANK 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.625 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH5.625 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.00 MEGAHERTZ BLANK AND 32.00 MEGAHERTZ BLANK
INCLOSURE TYPEENCASED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.5 BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL HEIGHT1.250 INCHES NOMINAL
OVERALL LENGTH7.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.112 INCHES
OPERATING TEMP RANGE+0.0 TO 50.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION17.0 MEGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION2.00 MEGAHERTZ BLANK AND 32.00 MEGAHERTZ BLANK AND 80.00 MEGAHERTZ BLANK AND 1.00 GIGAHERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION2.0 MEGAHERTZ BLANK AND 32.0 MEGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0