5996-00-655-0305 AMPLIFIER,MAGNETIC Index 5910-00-655-0307 CAPACITOR,FIXED,PAPER DIELECTRIC

National Stock Number:
5915-00-655-0306

Federal Supply Class:
5915

National Item Identification Number:
006550306

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
100-186811872GULTON INDUSTRIES INC STANDARD ELECTRONICS DIV
4625483B150RAYTHEON COMPANY
A-1373A23939THE CAPTOR CORPORATION
A137323939THE CAPTOR CORPORATION
46254849956RAYTHEON COMPANY
46254854X10RAYTHEON COMPANY


Techincal Specification:
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 1ST RADIO INTERFERENCE 1ST FUNCTION
5.0 2ND RADIO INTERFERENCE 2ND FUNCTION
5.0 3RD RADIO INTERFERENCE 3RD FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
4 THREADED STUD OUTPUT 2ND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
1.15 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
1.15 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
OVERALL HEIGHT4.855 INCHES NOMINAL
BODY LENGTH3.000 INCHES NOMINAL
BODY HEIGHT4.000 INCHES NOMINAL
BODY WIDTH2.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.500 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.164 INCHES
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
INPUT TERMINAL MANUFACTURER CODE02660
INPUT TERMINAL IDENTIFICATIONM81511/02H14-09P
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE500.0 VOLTS AT SEA LEVEL
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 55.0
OPERATING TEMP RANGE-65.0 TO 71.0 DEG CELSIUS
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN


Click here to Register for Free 30-day Trial