| AVERAGE LIFE RATING IN HOURS | 20000.0 |
| BODY HEIGHT | 2.969 INCHES MAXIMUM |
| BODY LENGTH | 2.531 INCHES MAXIMUM |
| BODY WIDTH | 1.781 INCHES MAXIMUM |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 40.0 MINIMUM 1ST BAND PASS AND 6.0 MAXIMUM 1ST BAND PASS FIRST FUNCTION |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 40.0 MINIMUM 2ND BAND PASS AND 6.0 MAXIMUM 2ND BAND PASS SECOND FUNCTION |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.875 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.125 INCHES NOMINAL |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG GROUND THIRD FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG INPUT FIRST FUNCTION |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG OUTPUT SECOND FUNCTION |
| FREQUENCY BAND WIDTH PER FUNCTION | 1.475 KILOHERTZ 1ST BAND PASS AND 1.675 KILOHERTZ 1ST BAND PASS FIRST FUNCTION |
| FREQUENCY BAND WIDTH PER FUNCTION | 2.325 KILOHERTZ 2ND BAND PASS AND 2.525 KILOHERTZ 2ND BAND PASS SECOND FUNCTION |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | 600.0 OHMS 2ND BAND PASS SECOND FUNCTION |
| INPUT IMPEDANCE PER FUNCTION W/LOAD | 600.0 OHMS 1ST BAND PASS FIRST FUNCTION |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 0.0 1ST BAND PASS FIRST FUNCTION |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 0.0 2ND BAND PASS SECOND FUNCTION |
| OPERATING TEMP RANGE | -55.0 TO 70.0 CELSIUS |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 600.0 OHMS 1ST BAND PASS FIRST FUNCTION |
| OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | 600.0 OHMS 2ND BAND PASS SECOND FUNCTION |
| OVERALL HEIGHT | 3.281 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD(S) LOCATION NOT OTHERWISE SPECIFIED |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| NOMINAL THREAD SIZE | 0.164 INCHES |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-RESISTANCE 1ST BAND PASS FIRST FUNCTION |
| PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-RESISTANCE 2ND BAND PASS SECOND FUNCTION |
| REFERENCE FREQUENCY PER FUNCTION | 1.575 KILOHERTZ 1ST BAND PASS FIRST FUNCTION |
| REFERENCE FREQUENCY PER FUNCTION | 2.425 KILOHERTZ 2ND BAND PASS SECOND FUNCTION |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 1.15 KILOHERTZ 1ST BAND PASS AND 1.475 KILOHERTZ 1ST BAND PASS AND 1.675 KILOHERTZ 1ST BAND PASS AND 2.00 KILOHERTZ 1ST BAND PASS FIRST FUNCTION |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 2.00 KILOHERTZ 2ND BAND PASS AND 2.325 KILOHERTZ 2ND BAND PASS AND 2.525 KILOHERTZ 2ND BAND PASS AND 2.85 KILOHERTZ 2ND BAND PASS SECOND FUNCTION |
| STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |