5915-00-724-6635 FILTER,LOW PASS Index 5915-00-724-6637 FILTER,LOW PASS

National Stock Number:
5915-00-724-6636

Federal Supply Class:
5915

National Item Identification Number:
007246636

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
241-0379-0095104ALCATEL-LUCENT HOLDINGS INC.
241-0379-00013499ROCKWELL COLLINS, INC.
526-6286-0013499ROCKWELL COLLINS, INC.
241-0379-00095104ALCATEL-LUCENT HOLDINGS INC.


Techincal Specification:
BODY HEIGHT1.016 INCHES MAXIMUM
BODY LENGTH3.000 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH2.812 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS55.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.188 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.188 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TAB, SOLDER LUG GROUND 3RD FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION456.00 KILOHERTZ BLANK AND 504.00 KILOHERTZ BLANK
INCLOSURE TYPEHERMETICALLY SEALED
INPUT IMPEDANCE PER FUNCTION W/LOAD600.0 OHMS BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK
OVERALL LENGTH3.500 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE500.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
OPERATING TEMP RANGE-10.0 TO 65.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT600.0 OHMS BLANK
REFERENCE FREQUENCY PER FUNCTION480.0 KILOHERTZ BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION108.00 KILOHERTZ BLANK AND 456.00 KILOHERTZ BLANK AND 504.00 KILOHERTZ BLANK AND 564.00 KILOHERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
SPECIAL FEATURESTERMINALS ON ONE SURFACE


Click here to Register for Free 30-day Trial