FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
1156010P494117BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
64D1340001341MICROPHASE CORP


Techincal Specification:
BODY LENGTH1.880 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.000 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND 1.6 MAXIMUM BLANK 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.000 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION5.97 GIGAHERTZ BLANK AND 6.02 GIGAHERTZ BLANK
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 OHMS BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.6 BLANK
OVERALL HEIGHT1.060 INCHES NOMINAL
OVERALL LENGTH3.480 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
OPERATING TEMP RANGE+0.0 TO 85.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT50.0 OHMS BLANK
REFERENCE FREQUENCY PER FUNCTION6.0 GIGAHERTZ BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION5.80 GIGAHERTZ BLANK AND 5.97 GIGAHERTZ BLANK AND 6.02 GIGAHERTZ BLANK AND 6.20 GIGAHERTZ BLANK 1ST FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO PER FUNCTION2.1 BLANK