5915-00-828-8369 FILTER,RADIO FREQUENCY INTERFERE Index 6145-00-828-8371 WIRE,ELECTRICAL

National Stock Number:
5915-00-828-8370

Federal Supply Class:
5915

National Item Identification Number:
008288370

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
218-00706-180378TRIUMPH AEROSTRUCTURES, LLC
601814403640LOCKHEED MARTIN CORPORATION
60181440B6S1INTERNATIONAL BUSINESS MACHINES CORP PARTS ORDER CENTER DEPT E - 54
SP-18313619EMS DEVELOPMENT CORPORATION
601814430874INTERNATIONAL BUSINESS MACHINES CORPORATION
JN14-2757A56289SPRAGUE ELECTRIC CO WORLD HQS
SP-18381831FILTRON CO INC DIV OF RFI CORP


Techincal Specification:
AVERAGE LIFE RATING IN HOURS2000.0
BODY HEIGHT1.094 INCHES MINIMUM AND 1.156 INCHES MAXIMUM
BODY LENGTH1.781 INCHES MINIMUM AND 1.843 INCHES MAXIMUM
BODY WIDTH1.094 INCHES MINIMUM AND 1.156 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.109 INCHES MINIMUM AND 2.141 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 THREADED STUD INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 WIRE LEAD OUTPUT 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL LENGTH2.088 INCHES MINIMUM AND 2.936 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE800.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 BLANK
OPERATING TEMP RANGE-55.0 TO 100.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION130.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ420.0 BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
UNTHREADED MOUNTING HOLE DIAMETER0.156 INCHES NOMINAL