6145-00-849-7428 CABLE,RADIO FREQUEN Index 6145-00-849-7431 CABLE,RADIO FREQUENCY

National Stock Number:
5915-00-849-7430

Federal Supply Class:
5915

National Item Identification Number:
008497430

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
049-00020726916NORTHROP GRUMMAN SYSTEMS CORPORATION
049-00020756289SPRAGUE ELECTRIC CO WORLD HQS


Techincal Specification:
BODY HEIGHT1.938 INCHES NOMINAL
BODY MATERIALALUMINUM
BODY LENGTH5.000 INCHES NOMINAL
BODY WIDTH3.156 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.562 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.562 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 RECTANGULAR FLANGE GROUND 3RD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY8 TAB, SOLDER LUG OUTPUT AND 13 RECTANGULAR FLANGE OUTPUT 2ND FUNCTION
FEATURES PROVIDEDCORROSION RESISTANT AND SHOCK RESISTANT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL IDENTIFICATIONSMA-RECEPTACLE
INPUT TERMINAL MANUFACTURER CODE26916
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
OVERALL HEIGHT2.938 INCHES NOMINAL
OVERALL LENGTH5.750 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE250.0 VOLTS AT SEA LEVEL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE200.0 VOLTS AT SEA LEVEL
MAXIMUM VOLTAGE DROP PER FUNCTION0.3 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION0.3 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION0.3 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION0.3 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION0.6 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION0.6 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE ALL FUNCTIONS
NOMINAL THREAD SIZE0.164 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 6TH RADIO INTERFERENCE 6TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING TEMP RANGE-65.0 TO 125.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION100.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION100.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION125.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
SPECIAL FEATURESTWENTY-ONE FILTERED FUNCTIONS
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON THREE SURFACES
VIBRATION RESISTANCE RANGE IN HERTZ+5.0 TO 1500.0


Click here to Register for Free 30-day Trial