5915-00-931-7195 FILTER,BAND PASS Index 6625-00-931-7197 AMMETER

National Stock Number:
5915-00-931-7196

Federal Supply Class:
5915

National Item Identification Number:
009317196

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
7644913-103538LOCKHEED MARTIN CORPORATION
7644913-118212AMERICAN TRANS-COIL CORP
7644913-1REVC03538LOCKHEED MARTIN CORPORATION
7644913-1REVE03538LOCKHEED MARTIN CORPORATION
B134708715CEN ELECTRONICS A DIV OF CHLORIDE POWER ELECTRONICS INC


Techincal Specification:
BODY HEIGHT4.800 INCHES NOMINAL
BODY MATERIALMETAL
BODY LENGTH5.200 INCHES NOMINAL
BODY WIDTH4.250 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM 2ND BAND PASS AND 3.5 MAXIMUM 2ND BAND PASS AND 55.0 MINIMUM 2ND BAND PASS 2ND FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM 1ST BAND PASS AND 3.5 MAXIMUM 1ST BAND PASS AND 55.0 MINIMUM 1ST BAND PASS 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.437 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 TURRET INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY4 TURRET OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION11.825 KILOHERTZ 1ST BAND PASS AND 11.975 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION11.825 KILOHERTZ 2ND BAND PASS AND 11.975 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD2.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
INPUT IMPEDANCE PER FUNCTION W/LOAD2.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS13.0 1ST BAND PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS13.0 2ND BAND PASS 2ND FUNCTION
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT2.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT2.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
OVERALL HEIGHT6.200 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY8 THREADED STUD
NOMINAL THREAD SIZE0.250 INCHES
OPERATING TEMP RANGE+15.0 TO 45.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION11.9 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
REFERENCE FREQUENCY PER FUNCTION11.9 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
SPECIAL FEATURESUNPACKAGED UNIT WEIGHT: LB4.000
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION8.90 KILOHERTZ 1ST BAND PASS AND 11.825 KILOHERTZ 1ST BAND PASS AND 11.975 KILOHERTZ 1ST BAND PASS AND 14.90 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION8.90 KILOHERTZ 2ND BAND PASS AND 11.825 KILOHERTZ 2ND BAND PASS AND 11.975 KILOHERTZ 2ND BAND PASS AND 14.90 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE