DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 4.460 INCHES NOMINAL |
BODY HEIGHT | 1.547 INCHES NOMINAL |
BODY LENGTH | 3.000 INCHES NOMINAL |
BODY WIDTH | 5.000 INCHES NOMINAL |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG GROUND 3RD FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 23 TURRET INPUT 1ST FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 23 TURRET OUTPUT 2ND FUNCTION |
INCLOSURE TYPE | ENCASED |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.025 4TH RADIO INTERFERENCE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.025 5TH RADIO INTERFERENCE 5TH FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.025 6TH RADIO INTERFERENCE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.025 3RD RADIO INTERFERENCE |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.7 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.7 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING TEMP RANGE | -55.0 TO 105.0 DEG CELSIUS |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 200.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 25.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 25.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 25.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 50.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
OVERALL LENGTH | 3.975 INCHES NOMINAL |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 1.0 VOLTS AC 2ND RADIO INTERFERENCE |
MAXIMUM VOLTAGE DROP PER FUNCTION | 100.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 100.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE |
MAXIMUM VOLTAGE DROP PER FUNCTION | 100.0 MILLIVOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
MAXIMUM VOLTAGE DROP PER FUNCTION | 100.0 MILLIVOLTS DC 6TH RADIO INTERFERENCE |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE 2ND FUNCTION |
MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
SPECIAL FEATURES | 23 FUNCTIONS |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 2000.0 |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |