5960-00-933-9181 ELECTRON TUBE Index 5950-00-933-9194 TRANSFORMER,POWER AUTOTRANSFORME

National Stock Number:
5915-00-933-9192

Federal Supply Class:
5915

National Item Identification Number:
009339192

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
1001023094OCEAN TECHNOLOGY INC
5003-274513050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON


Techincal Specification:
BODY HEIGHT2.000 INCHES NOMINAL
BODY LENGTH2.500 INCHES NOMINAL
BODY WIDTH1.500 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY3 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
INCLOSURE TYPEENCASED
OVERALL LENGTH5.880 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED HOLE 2ND FUNCTION
NOMINAL THREAD SIZE0.112 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 5TH RADIO INTERFERENCE 5TH FUNCTION
OPERATING TEMP RANGE-65.0 TO 160.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION


Click here to Register for Free 30-day Trial