5945-00-938-1138 RELAY,ELECTROMAGNETIC Index 5905-00-938-1143 RESISTOR,FIXED,WIRE WOUND,INDUCT

National Stock Number:
5915-00-938-1139

Federal Supply Class:
5915

National Item Identification Number:
009381139

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
FR6PX22PC181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M18327/007-02581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-F-18327/781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILF18327-781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
AVERAGE LIFE RATING IN HOURS10000.0
BODY HEIGHT2.500 INCHES MINIMUM AND 2.624 INCHES MAXIMUM
BODY LENGTH4.875 INCHES MINIMUM AND 4.999 INCHES MAXIMUM
BODY WIDTH2.500 INCHES MINIMUM AND 2.624 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS35.0 MINIMUM BLANK AND 3.0 MAXIMUM BLANK 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION552.50 HERTZ BLANK AND 637.50 HERTZ BLANK
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD600.0 OHMS BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS8.0 BLANK
OVERALL HEIGHT3.124 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE500.0 VOLTS AT SEA LEVEL
OPERATING TEMP RANGE-55.0 TO 65.0 CELSIUS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT600.0 OHMS BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
REFERENCE FREQUENCY PER FUNCTION595.0 HERTZ BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION467.50 HERTZ BLANK AND 552.50 HERTZ BLANK AND 637.50 HERTZ BLANK AND 722.50 HERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
TEST DATA DOCUMENT81349-MILF18327-7 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 2000.0


Click here to Register for Free 30-day Trial