5961-00-945-4900 TRANSISTOR Index 5950-00-945-4903 REACTOR

National Stock Number:
5915-00-945-4902

Federal Supply Class:
5915

National Item Identification Number:
009454902

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
526-2864-01095105ROCKWELL COLLINS, INC.
FS9454-90256662FREQUENCY SELECTIVE NETWORKS, INC.


Techincal Specification:
AVERAGE LIFE RATING IN HOURS10000.0
BODY HEIGHT3.188 INCHES MAXIMUM
BODY LENGTH2.425 INCHES MAXIMUM
BODY WIDTH1.875 INCHES MAXIMUM
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 1ST BAND PASS AND 3.0 NOMINAL 1ST BAND PASS 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS30.0 MINIMUM 2ND BAND PASS AND 3.0 NOMINAL 2ND BAND PASS 2ND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.234 INCHES MINIMUM AND 1.266 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.195 INCHES MINIMUM AND 2.005 INCHES MAXIMUM
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TURRET INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY6 TURRET OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION1.755 HERTZ 2ND BAND PASS AND 1.875 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION875.00 HERTZ 1ST BAND PASS AND 995.00 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 1ST BAND PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 2ND BAND PASS 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION20.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION20.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
OVERALL HEIGHT3.562 INCHES MAXIMUM
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE100.0 VOLTS AT ALTITUDE
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
OPERATING TEMP RANGE-20.0 TO 71.0 CELSIUS
REFERENCE FREQUENCY PER FUNCTION1.115 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
REFERENCE FREQUENCY PER FUNCTION1.995 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION150.0 OHMS 1ST BAND PASS 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION150.0 OHMS 2ND BAND PASS 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.485 KILOHERTZ 2ND BAND PASS AND 1.755 KILOHERTZ 2ND BAND PASS AND 1.875 KILOHERTZ 2ND BAND PASS AND 2.785 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION500.00 HERTZ 1ST BAND PASS AND 875.00 HERTZ 1ST BAND PASS AND 995.00 HERTZ 1ST BAND PASS AND 1.705 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
VIBRATION RESISTANCE RANGE IN HERTZ+10.0 TO 55.0