5910-00-951-9149 CAPACITOR,FIXED,CERAMIC DIELECTR Index 4710-00-951-9154 TUBE,METALLIC

National Stock Number:
5915-00-951-9152

Federal Supply Class:
5915

National Item Identification Number:
009519152

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
4801682340L3HARRIS TECHNOLOGIES, INC.


Techincal Specification:
BODY HEIGHT1.375 INCHES NOMINAL
BODY LENGTH3.031 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH2.250 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM 2ND BAND PASS AND 3.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM 1ST BAND PASS AND 3.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.750 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 COMPONENT SOCKET INPUT-OUTPUT/GROUND
FREQUENCY BAND WIDTH PER FUNCTION12.60 KILOHERTZ 1ST BAND PASS AND 13.60 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION12.60 KILOHERTZ 2ND BAND PASS AND 13.60 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
INCLOSURE TYPEENCASED
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
INPUT IMPEDANCE PER FUNCTION W/LOAD50.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 1ST BAND PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS1.0 2ND BAND PASS 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION100.0 KILOHMS BLANK
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT100.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT100.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-RESISTANCE 1ST BAND PASS 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-RESISTANCE 2ND BAND PASS 2ND FUNCTION
REFERENCE FREQUENCY PER FUNCTION13.1 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
REFERENCE FREQUENCY PER FUNCTION13.1 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 KILOHMS BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION11.30 KILOHERTZ 2ND BAND PASS AND 12.60 KILOHERTZ 2ND BAND PASS AND 13.60 KILOHERTZ 2ND BAND PASS AND 15.00 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION11.30 KILOHERTZ 1ST BAND PASS AND 12.60 KILOHERTZ 1ST BAND PASS AND 13.60 KILOHERTZ 1ST BAND PASS AND 15.00 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE