5915-01-049-4172 FILTER,BAND PASS Index 5930-01-049-4174 SWITCH,THERMOSTATIC

National Stock Number:
5915-01-049-4173

Federal Supply Class:
5915

National Item Identification Number:
010494173

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
155-1927338CRANE ELECTRONICS, INC.
155-327338CRANE ELECTRONICS, INC.
20-812518-607397GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS INC. DBA GENERAL DYNAMICS ADVANCED INFORMATION SYSTEMS


Techincal Specification:
BODY HEIGHT1.720 INCHES NOMINAL
BODY LENGTH1.620 INCHES NOMINAL
BODY WIDTH2.130 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 NOMINAL 1ST BAND PASS AND 1.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 NOMINAL 2ND BAND PASS AND 1.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.750 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.000 INCHES NOMINAL
FREQUENCY BAND WIDTH PER FUNCTION12.00 GIGAHERTZ 1ST BAND PASS AND 18.00 GIGAHERTZ 1ST BAND PASS 1ST FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION12.00 GIGAHERTZ 2ND BAND PASS AND 18.00 GIGAHERTZ 2ND BAND PASS 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.5 1ST BAND PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS2.5 2ND BAND PASS 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST BAND PASS 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND BAND PASS 2ND FUNCTION
OVERALL HEIGHT1.970 INCHES NOMINAL
OVERALL LENGTH2.370 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.138 INCHES
REFERENCE FREQUENCY PER FUNCTION15.0 GIGAHERTZ 1ST BAND PASS 1ST FUNCTION
REFERENCE FREQUENCY PER FUNCTION15.0 GIGAHERTZ 2ND BAND PASS 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST BAND PASS 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND BAND PASS 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION11.725 GIGAHERTZ 2ND BAND PASS AND 11.992 GIGAHERTZ 2ND BAND PASS AND 18.008 GIGAHERTZ 2ND BAND PASS AND 18.275 GIGAHERTZ 2ND BAND PASS 2ND FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION11.725 GIGAHERTZ 1ST BAND PASS AND 11.992 GIGAHERTZ 1ST BAND PASS AND 18.008 GIGAHERTZ 1ST BAND PASS AND 18.275 GIGAHERTZ 1ST BAND PASS 1ST FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON THREE SURFACES
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION12.0 GIGAHERTZ 1ST BAND PASS AND 18.0 GIGAHERTZ 1ST BAND PASS 1ST FUNCTION
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION12.0 GIGAHERTZ 2ND BAND PASS AND 18.0 GIGAHERTZ 2ND BAND PASS 2ND FUNCTION
VOLTAGE STANDING WAVE RATIO PER FUNCTION2.0 1ST BAND PASS 1ST FUNCTION
VOLTAGE STANDING WAVE RATIO PER FUNCTION2.0 2ND BAND PASS 2ND FUNCTION