5915-01-050-0528 FILTER,RADIO FREQUENCY INTERFERE Index 5915-01-050-0530 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-050-0529

Federal Supply Class:
5915

National Item Identification Number:
010500529

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
136FDE1601456MICROWAVE DEVELOPMENT LABORATORIES, INC.
395AS15930003NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
F320912598RLC ELECTRONICS, INC
FX20-0736-0157032DADEN-ANTHONY ASSOCIATES INC SUB OF TRAK MICROWAVE
7090261453RS MICROWAVE CO INC


Techincal Specification:
AVERAGE POWER RATING PER FUNCTION50.0 WATTS BLANK
BODY LENGTH5.040 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH10.800 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM BLANK AND 50.0 MAXIMUM BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION135.50 MEGAHERTZ BLANK AND 137.70 MEGAHERTZ BLANK
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS0.5 BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL HEIGHT3.000 INCHES MAXIMUM
OVERALL LENGTH6.500 INCHES NOMINAL
OVERALL WIDTH18.500 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY6 SLOT
MOUNTING SLOT WIDTH0.750 INCHES NOMINAL
OPERATING TEMP RANGE-30.0 TO 70.0 CELSIUS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE BLANK
REFERENCE FREQUENCY PER FUNCTION136.6 MEGAHERTZ BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION129.60 MEGAHERTZ BLANK AND 135.50 MEGAHERTZ BLANK AND 137.70 MEGAHERTZ BLANK AND 143.60 MEGAHERTZ BLANK
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION135.5 MEGAHERTZ BLANK AND 137.7 MEGAHERTZ BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK