5915-01-056-5140 FILTER,BAND PASS Index 5930-01-056-5142 SWITCH,THERMOSTATIC

National Stock Number:
5915-01-056-5141

Federal Supply Class:
5915

National Item Identification Number:
010565141

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
008067-3058R3GE AVIATION SYSTEMS LLC
008067-319623GE AVIATION SYSTEMS LLC
GF5503507294GENISCO FILTER CORP
GF5503513050SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
008067-335012GE AVIATION SYSTEMS LLC


Techincal Specification:
OPERATING CURRENT RATING PER FUNCTION IN AMPS4.5 1ST RADIO INTERFERENCE 1ST FUNCTION
4.5 2ND RADIO INTERFERENCE 2ND FUNCTION
4.5 3RD RADIO INTERFERENCE 3RD FUNCTION
4.5 4TH RADIO INTERFERENCE 4TH FUNCTION
4.5 5TH RADIO INTERFERENCE 5TH FUNCTION
4.5 6TH RADIO INTERFERENCE 6TH FUNCTION
INCLOSURE TYPEENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
8 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
MOUNTING FACILITY TYPE AND QUANTITY8 THREADED HOLE
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE AND
28.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
115.0 VOLTS AC 2ND RADIO INTERFERENCE AND
28.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
115.0 VOLTS AC 3RD RADIO INTERFERENCE AND
28.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
115.0 VOLTS AC 4TH RADIO INTERFERENCE AND
28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
115.0 VOLTS AC 5TH RADIO INTERFERENCE AND
28.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
115.0 VOLTS AC 6TH RADIO INTERFERENCE AND
28.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
400.0 4TH RADIO INTERFERENCE 4TH FUNCTION
400.0 5TH RADIO INTERFERENCE 5TH FUNCTION
400.0 6TH RADIO INTERFERENCE 6TH FUNCTION
MAXIMUM VOLTAGE DROP PER FUNCTION3.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
3.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
3.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
3.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
3.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
3.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
OVERALL HEIGHT4.275 INCHES MAXIMUM
BODY LENGTH3.000 INCHES MAXIMUM
BODY HEIGHT4.000 INCHES MAXIMUM
BODY WIDTH2.000 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.500 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.500 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.112 INCHES
SPECIAL FEATURES8 FUNCTIONS
MAXIMUM TEMP RISE25.0 DEG CELSIUS
INPUT TERMINAL MANUFACTURER CODE03554
INPUT TERMINAL IDENTIFICATION348-40E16-14S1
OPERATING TEMP RANGE0.0 TO 71.0 DEG CELSIUS
BODY MATERIALMETAL
BODY SURFACE TREATMENTTIN
THE MANUFACTURERS DATA
MANUFACTURERS CODE058R3
DESIGN CONTROL REFERENCE008067-3