OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 5.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 3.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 3.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
INCLOSURE TYPE | ENCASED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION |
| 4 TURRET OUTPUT 2ND FUNCTION |
| 1 TURRET GROUND 3RD FUNCTION |
MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED HOLE |
STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 113.5 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 113.5 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
| 28.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
| 28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
| 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
BODY LENGTH | 4.500 INCHES NOMINAL |
BODY HEIGHT | 4.000 INCHES NOMINAL |
BODY WIDTH | 1.750 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.875 INCHES NOMINAL |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.000 INCHES NOMINAL |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
NOMINAL THREAD SIZE | 0.138 INCHES |
INPUT TERMINAL MANUFACTURER CODE | 96906 |
INPUT TERMINAL IDENTIFICATION | MS27034H-14B-7P-EN |
BODY MATERIAL | METAL |