5915-01-135-8160 FILTER,RADIO FREQUENCY INTERFERE Index 5915-01-135-8162 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-135-8161

Federal Supply Class:
5915

National Item Identification Number:
011358161

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
13216E451797403CECOM LR CENTER
5JX10082484CVG SPRAGUE DEVICES, LLC
E-179123160LINDGREN RF ENCLOSURES INC ELMAG DIV
A-626723939THE CAPTOR CORPORATION
FC-226656528FIL-COIL INTERNATIONAL LLC
M133059901MTK ELECTRONICS INC
RF1178213619EMS DEVELOPMENT CORPORATION


Techincal Specification:
BODY LENGTH3.438 INCHES NOMINAL
BODY MATERIALMETAL
BODY OUTSIDE DIAMETER1.250 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION
FEATURES PROVIDEDNUT AND WASHER
INCLOSURE TYPEHERMETICALLY SEALED
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC BLANK AND 600.0 VOLTS DC BLANK
OVERALL LENGTH4.345 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE500.0 VOLTS AT SEA LEVEL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE1.2 KILOVOLTS AT SEA LEVEL
MAXIMUM TEMP RISE25.0 CELSIUS
MAXIMUM VOLTAGE DROP PER FUNCTION0.2 VOLTS DC BLANK
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
MOUNTING FACILITY TYPE AND QUANTITY1 THREADED BUSHING
NOMINAL THREAD SIZE0.438 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 BLANK
OPERATING TEMP RANGE-55.0 TO 125.0 CELSIUS
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ60.0 BLANK
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONCAPACITANCE-INDUCTANCE BLANK
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
STYLE DESIGNATORROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES