5945-01-139-0506 RELAY,ELECTROMAGNETIC Index 5950-01-139-0508 TRANSFORMER

National Stock Number:
5915-01-139-0507

Federal Supply Class:
5915

National Item Identification Number:
011390507

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
352390-33B150RAYTHEON COMPANY
352390-349956RAYTHEON COMPANY
352390-354X10RAYTHEON COMPANY


Techincal Specification:
BODY HEIGHT3.003 INCHES NOMINAL
BODY LENGTH3.507 INCHES NOMINAL
BODY MATERIALMETAL
BODY WIDTH1.758 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.250 INCHES NOMINAL
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 1ST BAND PASS AND 40.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS3.0 MINIMUM 2ND BAND PASS AND 40.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.250 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TURRET INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY2 TURRET OUTPUT 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.80 KILOHERTZ 2ND BAND PASS AND 5.60 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
FREQUENCY BAND WIDTH PER FUNCTION2.80 KILOHERTZ 1ST BAND PASS AND 5.60 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 1ST BAND PASS 1ST FUNCTION
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 2ND BAND PASS 2ND FUNCTION
LOAD IMPEDANCE PER FUNCTION10.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION10.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
OVERALL HEIGHT3.283 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
MOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE
NOMINAL THREAD SIZE0.138 INCHES
OPERATING TEMP RANGE-55.0 TO 85.0 CELSIUS
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST BAND PASS 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND BAND PASS 2ND FUNCTION
REFERENCE FREQUENCY PER FUNCTION4.2 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
REFERENCE FREQUENCY PER FUNCTION4.2 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION10.0 KILOHMS 2ND BAND PASS 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION10.0 KILOHMS 1ST BAND PASS 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 KILOHERTZ 1ST BAND PASS AND 2.80 KILOHERTZ 1ST BAND PASS AND 5.60 KILOHERTZ 1ST BAND PASS AND 11.00 KILOHERTZ 1ST BAND PASS 1ST FUNCTION
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION1.00 KILOHERTZ 2ND BAND PASS AND 2.80 KILOHERTZ 2ND BAND PASS AND 5.60 KILOHERTZ 2ND BAND PASS AND 11.00 KILOHERTZ 2ND BAND PASS 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE