3120-01-143-6758 BEARING,WASHER,THRUST Index 5915-01-143-6760 FILTER,BAND PASS

National Stock Number:
5915-01-143-6759

Federal Supply Class:
5915

National Item Identification Number:
011436759

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
6B53-69.98/9.3-050140K&L MICROWAVE LLC
978932-13B150RAYTHEON COMPANY
BP11/69.98-9.3-6AA0AEV7WILLIAM WHEELER
F-409312598RLC ELECTRONICS, INC
978932-149956RAYTHEON COMPANY
978932-154X10RAYTHEON COMPANY
R 351201341MICROPHASE CORP


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION69.984 MEGAHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS3.0 BLANK
INCLOSURE TYPEENCASED
FREQUENCY BAND WIDTH PER FUNCTION65.334 MEGAHERTZ BLANK AND
74.634 MEGAHERTZ BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
VOLTAGE STANDING WAVE RATIO PER FUNCTION1.5 BLANK
VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION67.484 MEGAHERTZ BLANK AND
72.484 MEGAHERTZ BLANK
OVERALL LENGTH5.250 INCHES NOMINAL
OVERALL HEIGHT1.000 INCHES NOMINAL
BODY LENGTH4.500 INCHES NOMINAL
BODY WIDTH1.250 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER0.120 INCHES MINIMUM AND
0.130 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.880 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.880 INCHES NOMINAL
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION45.00 MEGAHERTZ BLANK AND
65.334 MEGAHERTZ BLANK AND
74.634 MEGAHERTZ BLANK AND
95.00 MEGAHERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS60.0 MINIMUM BLANK AND
3.0 MAXIMUM BLANK 1ST FUNCTION
AVERAGE POWER RATING PER FUNCTION1.0 WATTS BLANK
AVERAGE LIFE RATING IN HOURS30000.0
VIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 200.0
OPERATING TEMP RANGE-46.0 TO 85.0 DEG CELSIUS


Click here to Register for Free 30-day Trial