5915-01-151-1268 FILTER,BAND PASS Index 5930-01-151-1270 SWITCH,PUSH

National Stock Number:
5915-01-151-1269

Federal Supply Class:
5915

National Item Identification Number:
011511269

Description:
FILTER,RADIO FREQUENCY INTERFERE

Detail:
An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.


Manufacturer Information:
865372-000206481NORTHROP GRUMMAN SYSTEMS CORPORATION
865372-000213973LITTON SYSTEMS INC. DIV NAVIGATION SYSTEMS DIVISION
RF0841313619EMS DEVELOPMENT CORPORATION
RF841313619EMS DEVELOPMENT CORPORATION


Techincal Specification:
BODY HEIGHT1.500 INCHES MAXIMUM
BODY LENGTH3.000 INCHES MAXIMUM
BODY MATERIALMETAL
BODY WIDTH2.500 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.100 INCHES NOMINAL
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET GROUND 3RD FUNCTION
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET OUTPUT 2ND FUNCTION
INCLOSURE TYPEHERMETICALLY SEALED
INPUT TERMINAL MANUFACTURER CODE96906
INPUT TERMINAL IDENTIFICATIONMS3472E8-33P
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
LOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
OVERALL LENGTH3.732 INCHES NOMINAL
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE450.0 VOLTS AT SEA LEVEL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
NOMINAL THREAD SIZE0.190 INCHES
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING CURRENT RATING PER FUNCTION IN AMPS1.0 2ND RADIO INTERFERENCE 2ND FUNCTION
OPERATING TEMP RANGE-54.0 TO 90.0 CELSIUS
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION150.0 VOLTS AC 1ST RADIO INTERFERENCE AND 450.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION150.0 VOLTS AC 2ND RADIO INTERFERENCE AND 450.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
PRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES