BODY HEIGHT | 1.650 INCHES NOMINAL |
BODY OUTSIDE DIAMETER | 0.437 INCHES NOMINAL |
BODY SURFACE TREATMENT | TIN |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 60.0 MINIMUM 2ND BAND PASS AND 3.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION |
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 60.0 MINIMUM 1ST BAND PASS AND 3.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.750 INCHES NOMINAL |
DISTANCE BETWEEN MOUNTING SURFACE AND LOWER END | 0.7212 INCHES NOMINAL |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG GROUND 3RD FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG INPUT 1ST FUNCTION |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
FREQUENCY BAND WIDTH PER FUNCTION | 500.30 KILOHERTZ 1ST BAND PASS AND 503.50 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
FREQUENCY BAND WIDTH PER FUNCTION | 500.30 KILOHERTZ 2ND BAND PASS AND 503.50 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
INCLOSURE TYPE | HERMETICALLY SEALED |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.5 1ST BAND PASS 1ST FUNCTION |
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 5.5 2ND BAND PASS 2ND FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST BAND PASS 1ST FUNCTION |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND BAND PASS 2ND FUNCTION |
OVERALL HEIGHT | 2.562 INCHES NOMINAL |
OVERALL LENGTH | 1.000 INCHES NOMINAL |
OVERALL WIDTH | 0.670 INCHES NOMINAL |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 100.0 VOLTS AT SEA LEVEL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
OPERATING TEMP RANGE | -30.0 TO 85.0 CELSIUS |
REFERENCE FREQUENCY PER FUNCTION | 501.9 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
REFERENCE FREQUENCY PER FUNCTION | 501.9 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST BAND PASS 1ST FUNCTION |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND BAND PASS 2ND FUNCTION |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 499.20 KILOHERTZ 1ST BAND PASS AND 500.30 KILOHERTZ 1ST BAND PASS AND 503.50 KILOHERTZ 1ST BAND PASS AND 505.30 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 499.20 KILOHERTZ 2ND BAND PASS AND 500.30 KILOHERTZ 2ND BAND PASS AND 503.50 KILOHERTZ 2ND BAND PASS AND 505.30 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
UNTHREADED MOUNTING HOLE DIAMETER | 0.128 INCHES NOMINAL |
VIBRATION RESISTANCE RANGE IN HERTZ | +10.0 TO 55.0 |