5915-01-161-3273 FILTER,BAND PASS Index 5915-01-161-3278 FILTER,RADIO FREQUENCY INTERFERE

National Stock Number:
5915-01-161-3275

Federal Supply Class:
5915

National Item Identification Number:
011613275

Description:
FILTER,BAND PASS

Detail:
An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).


Manufacturer Information:
28880-00156187CRYSTAL SOKOL PRODUCTS INC
293-1299-0110F961K S ELECTRONICS, L.L.C.
2B43500136MICROSEMI CORP. - HIGH PERFORMANCE TIMING
293-1299-01113499ROCKWELL COLLINS, INC.
293-1299-0111HP10KEMTEK XTALS INC
293-1299-01158997VECTRON INTERNATIONAL, INC.
FTR-288800S4G1PRECISION DEVICES, INC.
715725120PIEZO TECHNOLOGY INCORPORATED


Techincal Specification:
REFERENCE FREQUENCY PER FUNCTION70.0 MEGAHERTZ BLANK
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS5.0 BLANK
INCLOSURE TYPEHERMETICALLY SEALED
FREQUENCY BAND WIDTH PER FUNCTION69.955 MEGAHERTZ BLANK AND
70.045 MEGAHERTZ BLANK
FUNCTIONAL TERMINAL TYPE AND QUANTITY1 PIN INPUT 1ST FUNCTION
1 PIN OUTPUT 2ND FUNCTION
2 PIN GROUND 3RD FUNCTION
STYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
SOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION50.0 OHMS BLANK
OVERALL LENGTH1.760 INCHES NOMINAL
BODY LENGTH1.400 INCHES NOMINAL
BODY HEIGHT0.450 INCHES NOMINAL
BODY WIDTH0.480 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED STUD
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.050 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
NOMINAL THREAD SIZE0.086 INCHES
TEST DATA DOCUMENT13499-293-1299 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION69.87 MEGAHERTZ BLANK AND
69.955 MEGAHERTZ BLANK AND
70.045 MEGAHERTZ BLANK AND
70.13 MEGAHERTZ BLANK
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS20.0 MINIMUM BLANK AND
3.0 MAXIMUM BLANK 1ST FUNCTION
OPERATING TEMP RANGE-55.0 TO 90.0 DEG CELSIUS