OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 BLANK |
INCLOSURE TYPE | HERMETICALLY SEALED |
FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG INPUT 1ST FUNCTION |
| 2 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
STYLE DESIGNATOR | ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS BLANK |
LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS BLANK |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC BLANK AND |
| 250.0 VOLTS DC BLANK |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 BLANK |
MAXIMUM VOLTAGE DROP PER FUNCTION | 0.14 VOLTS AC BLANK AND |
| 0.14 VOLTS DC BLANK |
OVERALL LENGTH | 0.982 INCHES MAXIMUM |
BODY LENGTH | 0.440 INCHES MAXIMUM |
BODY OUTSIDE DIAMETER | 0.400 INCHES NOMINAL |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNF |
NOMINAL THREAD SIZE | 0.250 INCHES |
PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE, MOUNTING END BLANK |
MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 600.0 VOLTS AT SEA LEVEL |
MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | 250.0 VOLTS AT SEA LEVEL |
VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 55.0 |
OPERATING TEMP RANGE | -65.0 TO 160.0 DEG FAHRENHEIT |